AC
OR DC BREAKER BOX
CODE APPROVED FOR LOW VOLTAGE DC OR AC
SQUARE D circuit breakers in their "QO" line are UL
listed for 12 and 24 volts DC circuits. Q-O circuit breakers are available from
10 amps up to 60amps, no higher. Therefore, these load centers can be used for
most DC lightning or appliance circuits, but NOT for inverter DC
connection. Also used for 120 volt AC circuits as a separate unit. Do not mix
voltages in same box!
9"W x 12-3/4"H x 4"D
We now stock model #QO612L100S, a six circuit load center. We ship it with two
20 amp QO-1205272 breakers included for the price others sell empty. The
remaining four empty breaker slots may be filled with breakers of your
choice.
| O-QO612 load center with two 20 amp breakers: $58 Shipping $10 |
 |
| O-QO Breakers 10, 15,
20, or 30 amp: please specify what size......
$14
each |
 |
| O-QO Breaker 60 amp
...... $18
each |
 |
INVERTER DISCONNECT
Main Battery Disconnect
by Xantrex
DC Rated Circuit Breaker designed for
connecting 1000 to 5500 watt inverter to battery safely. The 175 amp or 250 amp
circuit breaker / disconnect is enclosed to pass National Electric Code. Design matches other
Trace products.
Easily installs to inverter battery cable by cutting and connecting the positive cable
directly to the breaker. Accepts up to 4/0 cables directly in clamp terminals of
breaker.
Size 10-1/2"W x 21"H x 5"D
Consider Making Your Own Powercenter.
See
kit using this item.
O-DC250 250 amp DC breaker & box: $295 (Shipping $14)
For inverters over 1500 watt 12 volt; over 3000 watt 24 volt; and SW 5548 5500
watt 48 volt
|
 |
O-DC175 175 amp DC circuit breaker & box: $295
(Shipping $14)
For inverters 1000 watt up to 1500 watt at 12 volts; up to 3000 watts at 24
volts; and 3600-4000 watt 48 volt |
 |
| O-GJ250 second 250 amp breaker for second
inverter: $95 |
 |
| O-GJ175 second 175
amp breaker for second inverter: $95 |
 |
Extra breakers to fit the four knockout spaces in box edge:
| O-CD20: 20 amp DC $24 |
 |
| O-CD30: 30 amp DC $24 |
 |
| O-CD60: 60 amp DC $24 |
 |
| O-CD80: 80 amp DC $24 |
 |
| O-CD100: 100 amp DC $36 |
 |
A negative terminal block to join more negative / ground wires within box.
Joins four 4/0 cables & two 1/0, & two #2, & four #4 wires.
| O-DCBB: $70 |
 |

Return to the top
AC and DC Disconnect Boxes by Outback

FLEXWARE 500 DC 18.2 H x 11.4 W x 12.1 D
ETL listed indoor enclosure includes the following items:
One main inverter breaker: 100, 175, or 250 amps
Knockouts for one more inverter breaker and eight smaller load/input breakers or
five smaller load/input breakers plus one GFP/2 ground fault protector
500 amp 50 millivolt DC current shunt
Battery (+) and (-) bus bars
Knockouts on Five surfaces for conduit, cable clamps, and MX60 grommets
| O-FLEX500DC-100....shipping $18......$335
|
 |
| O-FLEX500DC-175....shipping $18......$395
|
 |
| O-FLEX500DC-250....shipping $18......$395 |
 |
Extra Large Inverter Breakers for the
FLEXWARE 500 DC Disconnect Box
| O-OBDC-100: $59
|
 |
| O-OBDC-175: $129 |
 |
| O-OBDC-250: $129
|
 |
MX60 Mounting Bracket, plus Smaller Input and Load Breakers for the
FLEXWARE 500 DC
Disconnect Box: please note that no small breakers are included with the
FLEXWARE 500 DC
box
| O-FLEXCCB: mounting bracket for one side mounted
Outback MX60 controller: $39 |
 |
| O-OBDC 5, 10, 15, 20, or 30.......please
specify size.....$25 |
 |
| O-OBDC 40, 50, 60, 70, or 80......please specify size.....$25
|
 |
DC Ground Fault Protection System...Required
by NEC for PV arrays mounted on dwelling roof. The GFP/2 protects wiring and
system components for one or two arrays. Requires three small breaker spaces in
the FLEXWARE 500 DC box. Dual 80 amp breakers for 125VDC maximum Voc.
| O-OBDC-GFP/2.....$129
|
 |
Outback offers a Mounting Plate for the
FLEXWARE 500 DC, FLEXWARE 500 AC, and one to two inverters
| O-FLEXWARE500MP...........Shipping $18..............$169 |
 |

FLEXWARE 500 AC 18.2H x 11.4W x 12.1D
ETL listed indoor enclosure includes the following items:
Dual 60 amp Inverter bypass breaker
Dual 60 amp AC input breaker
Dual 60 amp AC output breaker
Ground Bus Bar
One insulated AC neutral bus bar
Two insulated black AC Hot bus bars
Two insulated red AC Hot bus bars
Knockouts for 10 additional Outback AC breakers and provisions for mounting X240
transformer
Flex conduit to run between Flexware AC and Flexware DC boxes
| O-FLEX500AC......shipping $18.......$495
|
 |
Single and Double pole AC Load Breakers for the
FLEXWARE 500 AC
Disconnect Box:
| O-OBAC 15, 20, 30, 50, or
60 single pole
breaker.......please specify size.....$19 |
 |
| O-OBAC 15D, 20D, 25D, 30D, 50D,
or 60D double pole breaker......please
specify size.....$39 |
 |
DC RATED FUSES
WITH FUSE HOLDER FOR
INVERTERS
Fuse blocks directly accept large inverter battery cables. A fuse and
holder is basic protection against electrical fires from over-current in wiring. Fuses and
holders by themselves are not accepted by National Fire Code unless mounted in an approved
metal box. Replacement fuses available from Backwoods if you do not find them
locally.
Minimum shipping $8 per whole order covers all items with
no shipping listed
SMALLER DC FUSES
|
FIVE FUSE
Block of five 15 amp auto type
AGC glass fuses, holder connects battery positive to top of all fuses. Screw terminal
bottom of each for loads. Low voltage DC only. 5 fuses & 5 spares.
| O-FIVE FUSE: $18 |
 |
|
 |
3 AMP IN-LINE FUSE & HOLDER
with wires. For meters and small items.
| O-IN-LINE: $3 |
 |
|
Minimum shipping charge $8 per order covers all items with no shipping listed

Return to the top
|